Alat Uji Keretakan Ultrasonic Flaw Detector seri MFD500B
- Display: Hi-resolution (320×240 pixels) multi-color TFT LCD with 4 user-selectable brightness control provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness. The hi-resolution multi-color TFT LCD display with fast 60 Hz update gives an “analog look” to the waveform providing detailed information that is critical in many applications including nuclear power plant inspections.
- Range: Up to 9999 mm in steel. suitable for use on large work pieces and in high-resolution measurements.
- Pulse: Pulse Energy selectable among Low, Medium and High.Pulse Width tunable from 0.1µs to 0.5 µs to match the probes with different frequency. Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments. Damping selectable among 100Ω、200Ω and 400Ω for optimum probe Performance: Test Modes include Pulse echo, dual and thru-transmission
- Receiver: Sampling:10 digit AD Converter at the sampling speed of 160 MHz; Rectification: Positive Half wave, Negative Half wave, Full wave and RF. Analog Bandwidth: 0.5MHz to 15MHz capability with selectable frequency ranges (automatically set by the Gain: 0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked. instrument) to match probe for optimum performance.
Ultrasonic Flaw Detector seri MFD500B
- Gates:
- Gate Start: Variable over entire displayed range
- Gate Width: Variable from Gate Start to end of displayed range
- Gate Height: Variable from 0 to 99% Full Screen Height
- Alarms: Threshold positive/negative
- Memory:
- Memory of 100 channel files to store calibration set-up
- Memory of 1000 wave files to store A-Scan patterns and instrument settings.
- All the files can be stored, recalled and cleared.
- Functions: Semiautomatic two point calibration: Automated calibration of transducer zero offset and/or material velocity
- Flaw Locating: Live display Sound-path, Projection (surface distance), Depth, Amplitude
- Flaw sizing: Automatic flaw sizing using AVG/AVG or DAC, speeds reporting of defect acceptance or rejection.
- Digital Readout and Trig. Function: Thickness/Depth can be displayed in digital readout when using a normal probe and Peam path, Surface Distance and Depth are directly displayed when angle probe is in use.
- Both the DAC and the AVG method of amplitude evaluation are available.
- Curved Surface Correction feature
- Crack Height Measure function
- Weld figure feature
- Magnify gate: spreading of the gate range over the entire screen width Video Recording and play Auto-gain function
- Envelope: Simultaneous display of live A-scan at 60 Hz update rate and envelope of A-scan display
- Peak Hold: Compare frozen peak waveforms to live A-Scans to easily interpret test results.
- A Scan Freeze: Display freeze holds waveform and sound path data B Scan display feature
- Real Time Clock
- The instrument clock keeps running tracking the time.
- Communication
- High speed USB2.0 port.
- The optional DataPro software helps manage and format stored inspection data for high-speed transfer to the PC. Data can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking.
- Battery: Internal rechargeable Li-ion battery pack rated 7.2V at 8800 mAh; 8 hours nominal operating time depending on display brightness 8-10 hours typical recharge time Knob
- Operating adjustments are easily and quickly made using the rotary knob.
- Specifications:
- Range: 0 to 9999 mm, at steel velocity
- Material Velocity: 1000 to 9999m/s
- Display Delay: -20 to 3400 µs
- Probe Delay/Zero Offset : 0 to 99.99µs
- Sensitivity: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB and locked.
- Test Modes: Pulse echo, dual element and thru-transmission
- Pulser: Tunable Square Wave Pulser
- Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
- Pulse Energy: Low, Medium and High
- Damping: 100, 200, 400 ohms
- Bandwidth (amplifier bandpass ): 0.5 to 15 MHz
- Gate Monitors: Two independent gates controllable over entire sweep range
- Rectification: Positive halfwave, negative halfwave, fullwave, RF
- System Linearity: Horizontal: +/-0.2% FSW, Vertical: 0.25% FSH, Amplifier
- Accuracy +/-1 dB.
- Reject (suppression): 0 to 80% full screen height
- Units: Inch or millimeter
- Transducer Connections: BNC or LEMO
- Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
- Dimensions: 263H×170W×61D mm
- Operating Temperature: -10℃ to 50℃
- Storage Temperature: -30℃ to 50℃
Ultrasonic Flaw Detector seri MFD500B